Rơle 3RH Siemens

Rơle 3RH Siemens

SP0329

Mời liên hệ

Auxiliary Relays

Product brand name SIRIUS
Product designation contactor relay
Product type designation 3RH2


General technical data

Size of contactor S00
Product extension
● Auxiliary switch Yes
Insulation voltage
● with degree of pollution 3 rated value 690 V
Degree of pollution 3
Surge voltage resistance rated value 6 kV
Protection class IP
● on the front IP20
Shock resistance at rectangular impulse
● at DC 10g / 5 ms, 5g / 10 ms
Shock resistance with sine pulse
● at DC 15g / 5 ms, 8g / 10 ms
Mechanical service life (switching cycles)
● of contactor typical 5 000 000
● of the contactor with added electronics
compatible auxiliary switch block typical
5 000 000
● of the contactor with added auxiliary switch
block typical
5 000 000


Ambient conditions

Installation altitude at height above sea level
● maximum 2 000 m
Ambient temperature
● during operation -25 ... +60 °C
● during storage -55 ... +80 °C


Main circuit

No-load switching frequency
● at AC 10 000 1/h
● at DC 10 000 1/h


Control circuit/ Control

Type of voltage of the control supply voltage DC
Control supply voltage at DC
● rated value 220 V
Closing power of magnet coil at DC 4 W
Holding power of magnet coil at DC 4 W
Closing delay
● at DC 30 ... 100 ms
Opening delay
● at DC 7 ... 13 ms
Arcing time 10 ... 15 ms


Auxiliary circuit

Number of NC contacts
● for auxiliary contacts 2
— instantaneous contact 2
Number of NO contacts
● for auxiliary contacts 2
— instantaneous contact 2
Identification number and letter for switching
elements
22 E
Operating current at AC-12 maximum 10 A
Operating current at AC-15
● at 230 V rated value 10 A
● at 400 V rated value 3 A
● at 500 V rated value 2 A
● at 690 V rated value 1 A
Operating current at 1 current path at DC-12
● at 24 V rated value 10 A
● at 110 V rated value 3 A
● at 220 V rated value 1 A
● at 440 V rated value 0.3 A
● at 600 V rated value 0.15 A
Operating current with 2 current paths in series at
DC-12
● at 24 V rated value 10 A
● at 60 V rated value 10 A
● at 110 V rated value 4 A
● at 220 V rated value 2 A
● at 440 V rated value 1.3 A
● at 600 V rated value 0.65 A
Operating current with 3 current paths in series at
DC-12
● at 24 V rated value 10 A
● at 60 V rated value 10 A
● at 110 V rated value 10 A
● at 220 V rated value 3.6 A
● at 440 V rated value 2.5 A
● at 600 V rated value 1.8 A
Operating frequency at DC-12 maximum 1 000 1/h
Operating current at 1 current path at DC-13
● at 24 V rated value 10 A
● at 110 V rated value 1 A
● at 220 V rated value 0.3 A
● at 440 V rated value 0.14 A
● at 600 V rated value 0.1 A
Operating current with 2 current paths in series at
DC-13
● at 24 V rated value 10 A
● at 60 V rated value 3.5 A
● at 110 V rated value 1.3 A
● at 220 V rated value 0.9 A
● at 440 V rated value 0.2 A
● at 600 V rated value 0.1 A
Operating current with 3 current paths in series at
DC-13
● at 24 V rated value 10 A
● at 60 V rated value 4.7 A
● at 110 V rated value 3 A
● at 220 V rated value 1.2 A
● at 440 V rated value 0.5 A
● at 600 V rated value 0.26 A
Operating frequency at DC-13 maximum 1 000 1/h
Design of the miniature circuit breaker
● for short-circuit protection of the auxiliary circuit
up to 230 V
C characteristic: 6 A; 0.4 kA
Contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)


UL/CSA ratings

Contact rating of auxiliary contacts according to UL A600 / Q600


Short-circuit protection

Design of the fuse link
● for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 10 A


Installation/ mounting/ dimensions

Mounting position +/-180° rotation possible on vertical mounting surface; can be
tilted forward and backward by +/- 22.5° on vertical mounting
surface
Mounting type screw and snap-on mounting onto 35 mm standard mounting rail
Height 57.5 mm
Width 90 mm
Depth 73 mm
Required spacing
● for grounded parts
— at the side 6 mm
● for live parts
— at the side 6 mm


Connections/Terminals

Type of electrical connection
● for auxiliary and control current circuit screw-type terminals
Type of connectable conductor cross-sections
● for auxiliary contacts
— single or multi-stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12


Safety related data

B10 value
● with high demand rate acc. to SN 31920 1 000 000; With 0.3 x Ie
Proportion of dangerous failures
● with low demand rate acc. to SN 31920 40 %
● with high demand rate acc. to SN 31920 73 %
Failure rate [FIT]
● with low demand rate acc. to SN 31920 100 FIT
Product function
● positively driven operation acc. to IEC 60947-5-
1
Yes
T1 value for proof test interval or service life acc. to
IEC 61508
20 y